Laserfiche WebLink
2.2 SOIL TREATMENT <br />A. Termiticide: Provide an EPA -registered termiticide complying with requirements of authorities having <br />jurisdiction, in an aqueous solution formulated to prevent termite infestation. Provide quantity required <br />for application at the label volume and rate for the maximum termiticide concentration allowed for each <br />specific use, according to product's EPA -Registered Label. <br />PART 3 - EXECUTION <br />3.1 EXAMINATION <br />A. Examine substrates, areas, and conditions, with Applicator present, for compliance with requirements <br />for moisture content of soil, interfaces with earthwork, slab and foundation work, landscaping, and other <br />conditions affecting performance of termite control. <br />1. Proceed with application only after unsatisfactory conditions have been corrected. <br />3.2 PREPARATION <br />A. General: Comply with the most stringent requirements of authorities having jurisdiction and with <br />manufacturer's written instructions for preparation before beginning application of termite control <br />treatment. Remove all extraneous sources of wood cellulose and other edible materials such as wood <br />debris, tree stumps and roots, stakes, formwork, and construction waste wood from soil within and around <br />foundations. <br />B. Soil Treatment Preparation: Remove foreign matter and impermeable soil materials that could decrease <br />treatment effectiveness on areas to be treated. Loosen, rake, and level soil to be treated except previously <br />compacted areas under slabs and footings. Termiticides may be applied before placing compacted fill <br />under slabs if recommended in writing by termiticide manufacturer. <br />1. Fit filling hose connected to water source at the site with a backflow preventer, complying with <br />requirements of authorities having jurisdiction. <br />3.3 APPLICATION, GENERAL <br />A. General: Comply with the most stringent requirements of authorities having jurisdiction and with <br />manufacturer's EPA -Registered Label for products. <br />3A APPLYING SOIL TREATMENT <br />A. Application: Mix soil treatment termiticide solution to a uniform consistency. Provide quantity required <br />for application at the label volume and rate for the maximum specified concentration of termiticide, <br />according to manufacturer's EPA -Registered Label, to the following so that a continuous horizontal and <br />vertical termiticidal barrier or treated zone is established around and under building construction. <br />Distribute treatment evenly. <br />Wabasso Beach Park <br />Indian River County <br />DAA Project No. 6008 <br />02361-3 <br />