My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2005-265
CBCC
>
Official Documents
>
2000's
>
2005
>
2005-265
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/29/2016 11:10:14 AM
Creation date
9/30/2015 9:00:55 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Work Order
Approved Date
08/02/2005
Control Number
2005-265
Agenda Item Number
11.I.2
Entity Name
Peninsula Hydrologic Data Specialists, Inc.
Subject
East Roseland Stormwater Improvement Project
Work Order No.1 Stormwater Samples
Area
Roseland Pond
Supplemental fields
SmeadsoftID
5114
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
East Roseland QAPP <br /> Section B <br /> Revision No . _ <br /> Date : 7/23/04 <br /> Page 19 of 22 <br /> perform the field data collection , sample collection and measurements to ensure <br /> consistency . <br /> Sampling protocols for this project that are not previously stated in the QAPP will <br /> adhere to the 62 - 160 April 9 , 2002 version of the SOPs . <br /> B5 . 2 QC and Corrective Action Procedures <br /> If sampling is suspended because the lake depth drops to a predetermined level <br /> within four hours after initiating sampling and the samplers shut off, Michael <br /> Wickwire will take corrective action and reset the automatic samplers and <br /> decontaminate the field equipment . <br /> The laboratory analyses shall be conducted by U . S . Biosystems , Inc . , 3231 NW <br /> 7 t Avenue , Boca Raton , Florida 33431 , telephone (888 ) 862- 5227 . U . S . <br /> Biosystems , Inc . currently operates under NELAC accreditation # E86240 <br /> expiring on June 30 , 2005 . Laboratory quality control procedures will adhere to <br /> the 62 - 160 April 9 , 2002 version of the SOPs . <br /> The types of laboratory control checks that will be used when analyzing samples <br /> for this project are : <br /> Chemical : <br /> o Reagent Blanks <br /> o Matrix Spikes <br /> o Duplicate Samples <br /> o QC Check Samples <br /> o Duplicate Matrix Spikes <br /> o QC Check Standards <br /> o Continuing Calibration Standards <br /> Michael Wickwire , Project Quality Assurance Officer, is responsible for all <br /> necessary corrective action related to sampling and reporting and adhere to the <br /> requirements in DEP -SOP-001 /01 January 1 , 2002 . <br />
The URL can be used to link to this page
Your browser does not support the video tag.