East Gifford QAPP <br /> Section B <br /> Revision No . <br /> Date : 3/ 16/05 <br /> Page 12 of 18 <br /> the samplers will shut off, since this will indicate a non -significant ra nfall event . <br /> All sampling intake points will be located near the influent pipe oreffluent weir <br /> (within ten to fifteen feet) , as applicable , and approximately mid -de th in the <br /> water column . <br /> The sample locations are shown on Figure A . 2 <br /> Pre-construction sampling will consist of three separate rainfall events (grab <br /> samples ) . Post-construction sampling will consist of six separate rainfall events <br /> (composite samples ) . <br /> All of the parameters that will be measured are for information . Since this project <br /> is a stormwater system retrofit , there is no critical parameter of concern . The <br /> purpose of the stormwater sampling is to determine the pollution removal <br /> effectiveness of the constructed stormwater system . <br /> B2 . Sampling Methods Requirements <br /> 62 . 1 Sample Collection Procedures and Methods <br /> Pre-construction stormwater samples will be collected manually . O le grab <br /> sample will be collected for each rainfall event measured . All samp es will be <br /> collected from a representative pool of stormwater ( mid depth ) and ill be <br /> collected in a large plastic container suitable for such sampling . Th a. sampling <br /> container will be properly decontaminated before each sampling evi nt . <br /> Automatic stormwater samplers will collect post-construction composite samples . <br /> Each automatic sampler will be equipped with a large plastic sample container <br /> that is properly cleaned before each sampling event . The automatic samplers <br /> will be programmed to take a flow-weighted sample every fifteen minutes . Once <br /> activated , each sampler will draw the flow-weighted sample through a Teflon <br /> tube , into its sample container every 15 minutes for approximately s x hours or <br /> until at least 4 , 800mL is collected . The composite sample containers will be <br /> thermally preserved during the collection process , then the composi a jug will be <br /> stirred and siphoned into lab-supplied bottles that have been properly chemically <br /> preserved , and the samples will be transported to the laboratory on ce in order <br /> to ensure proper preservation . <br /> The requirements of Chapter 62 -302 , April 9 , 2002 version of the S Ps will be <br /> met for field and analytical activities . <br /> B2 . 2 Equipment Needed for Sampling <br /> 1 . Pre-Construction — Large plastic sampling container with lid , small battery <br /> operated pump with Teflon or plastic suction and discharge tubing . <br /> F :\Public Works\KeithM\Stormwater Projects\Gifford East\Water Quality Monitoring Program\Quality Assurance Project Plan\DEP <br /> QAPP East Gifford Revision 3- 16-2005.doc <br />