Laserfiche WebLink
Sodding shall not be performed when weather and soil conditions are , in the <br /> Engineer' s opinion , unsuitable for proper results . <br /> Sod shall be placed around all structures , equipment pads , etc . <br /> I . Watering : The areas on which the sod is to be placed shall contain sufficient moisture , <br /> as determined by the Engineer , for optimum results . After being placed , the sod shall <br /> be kept in a moist condition to the full depth of the rooting zone for at least 2 weeks . <br /> Thereafter , the Contractor shall apply water as needed until the sod roots and starts to <br /> grow for a minimum of 60 days ( or until final acceptance , whichever is latest) . <br /> J . Maintenance : The Contractor shall , at his expense , maintain the sodded areas in a <br /> satisfactory condition until final acceptance of the project . Such maintenance shall <br /> include repairing of any damaged areas and replacing areas in which the <br /> establishment of the grass stand does not appear to be developing satisfactorily . <br /> Replanting or repair necessary due to the Contractor' s negligence , carelessness or <br /> failure to provide routine maintenance shall be at the Contractor' s expense . <br /> The Contractor shall maintain the sodded area up to the final acceptance date as <br /> directed by the Engineer . Grass height shall not exceed 6 " without mowing . Clippings <br /> shall be removed from sidewalk . <br /> K . Article 575 - 5 . The first two paragraphs under this Article are deleted and the <br /> following substituted : <br /> The contract unit price for sodding shall include the costs of sod , fertilizer ( 2 <br /> applications ) , sidewalk sweeping after mowing , mowing , pegging disposal of clippings , <br /> water , tools , equipment , labor and all other incidentals necessary . <br /> L . Payment shall be made under : <br /> Item No . : 570 - 1 -2 — Performance Turf ( Bahia ) - Per Square Yard <br /> SECTION - 00575 QUEEN AND WASHINGTON PALMS <br /> The work specified in this item shall conform to FDOT Index #544 and Section 580 of the <br /> Florida Department of Transportation Standard Specifications for Road and Bridge <br /> Construction ( 2010 ) . <br /> General Tree RELOCATION specifications : <br /> 12 each " Queen Palms " <br /> 15 each "Washington Palms " <br /> Trees are currently located at the southwest corner of 41 st on 66th Ave . The trees slated <br /> for removal will be selected by county staff ahead of time . The trees are being relocated to <br /> a new park entrance west of 58th Ave on 81St St . The trees placement has been identified <br /> 01025 -22 Technical Specifications <br /> F : \Public Works \ENGINEERING DIVISION PROJECTS \ 1047-2 IRC Fairgrounds Overflow & Vehicular Staging Phase 21Admim \bid <br /> documents\Technical Specifications . doc <br />