My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2012-041
CBCC
>
Official Documents
>
2010's
>
2012
>
2012-041
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2015 10:16:32 AM
Creation date
10/1/2015 4:07:54 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Work Order
Approved Date
02/21/2012
Control Number
2012-041
Agenda Item Number
15.B.3
Entity Name
Geosyntec Consultants
Subject
Work Order No. 3
Landfill Gas Flare Relocation Project
Area
Indian River County Class 1 Landfill
Archived Roll/Disk#
112-R-0001
Supplemental fields
SmeadsoftID
10952
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr . 1-limanshu Mehta <br /> 13 February 2012 <br /> Page 4 <br /> Specifications . The test results will be reviewed by the certification Engineer and the CQA <br /> Senior Engineering Technician . Summary reports of the laboratory conformance and field <br /> performance test results will be compiled for inclusion in the certification report for the overall <br /> Cell 1 — Segment 3 Expansion construction . It is also understood that Golder would provide <br /> surveying services including preparation of as - built record drawings pertaining to the gas flare <br /> relocation that would be signed and sealed by a registered surveyor for inclusion in the final <br /> certification report for the overall Cell 1 — Segment 3 Expansion construction . <br /> For budgeting purposes it has been assumed that the CQA Senior Engineering Technician will be <br /> on site during five (5 ) of the Contractor ' s 8 -week construction schedule , representing the <br /> duration of construction activities for which the project specifications requires CQA work . His <br /> presence on site will be limited to 8 hours/day , 3 days per week during the 5 weeks of the &week <br /> construction schedule . Geosyntec will coordinate with Contractor ' s construction crew to provide <br /> monitoring and testing services for the critical components of the construction project . <br /> Phase 3 : Construction Management and Engineering Support Services <br /> Geosyntec will also provide construction management (CM ) and engineering support services <br /> throughout the duration of the flare relocation schedule . CM activities will include conducting <br /> weekly to bi -weekly construction meetings with the contractor, and assisting the contractor in <br /> identifying critical construction tasks and material procurement activities . Geosyntec will also <br /> evaluate Contractor payment requests , verify quantities and conformance with the plans and <br /> specifications , and provide contract administration . <br /> As part of this phase , Geosyntec will review contractor ' s submittals for conformance with the <br /> project plans and specifications , and address any requests for clarification of information ( RCIs) <br /> and design change notices ( DCNs ) . Upon completion of construction , Geosyntec will draft <br /> construction completion letter for the SWDD Board ' s approval of contractor ' s final invoice . <br /> BUDGET ESTIMATE <br /> The following assumptions were used by Geosyntec in developing the budget estimate presented <br /> below : <br /> • The total project duration will be 8 weeks with an anticipated start date of 27 February <br /> 2012 . <br /> CQA monitoring is budgeted for 8 hours per day , 3 days per week (24 hours per week) <br /> for 5 weeks of the 8 -week construction schedule proposed by Golder . <br /> XLI2055 /.11 . 12014 11A2014Proposal for LFG Flare CQA & Lngineering support <br /> I `, I „ 1111111 - I1 lulu ) llm <br />
The URL can be used to link to this page
Your browser does not support the video tag.