Laserfiche WebLink
kk I In k IN IN IN <br /> IN IN I IN IN <br /> IN N4 I <br /> IN <br /> IN IN 14 <br /> 548-2 . 6 Backfill Material : <br /> 548-2 . 6. 1 General : Provide compacted select backfill or flowable fill within the <br /> retaining wall volume when the option for flowable fill is shown in the plans . The retaining wall <br /> volume is defined to extend from the top of the leveling pad or footing, or bottom of walls which <br /> do not have footing or leveling pads , to the finish grade line and from the face of the wall to a <br /> vertical plane passing through the end of the extreme wall component (straps , counterforts , etc . ) <br /> plus 1 foot. <br /> 548-2 . 6. 2 Compacted Select Backfill : Meet the requirements of Sections 105 <br /> and 120 except as noted within this Section . Have the backfill material tested for every soil type <br /> for pH, resistivity, sulfate and chloride content by a Department approved independent testing <br /> laboratory prior to placement. Provide certification to the Engineer, that the results have met the <br /> requirements of this Section and are signed and sealed by a Professional Engineer, registered in <br /> the State of Florida. <br /> For constructing the retaining wall volume , do not use backfill material <br /> containing more than 2 . 0 % by weight of organic material, as determined by FM 1 -T 267 and by <br /> averaging the test results for three randomly selected samples from each stratum or stockpile of a <br /> particular material . If an individual test value of the three samples exceeds 3 % , the stratum or <br /> stockpile will not be suitable for constructing the retaining wall volume . <br /> Ensure that the material is non-plastic as determined by AASHTO T 90 <br /> and the liquid limit as determined by AASHTO T 89 is less than 15 . The pH, as determined by <br /> FM 5 - 550 , shall not be lower than five and not higher than nine . <br /> Use backfill for walls using soil reinforcements that meets the following <br /> gradation limits determined in accordance with AASHTO T 27 and FM 1 -T 011 : <br /> Sieve Size Percent Passing <br /> 3 1 /2 inches 100 <br /> 3 /4 inch 70 - 100 <br /> No . 4 30- 100 <br /> No . 40 15400 <br /> No . 100 0- 65 <br /> No . 200 0 - 12 <br /> In addition, for permanent walls utilizing metallic soil reinforcement, use <br /> backfill that meets the following electro- chemical test criteria for determining corrosiveness : <br /> Criteria Test Method <br /> Resistivity: > 3000 ohm - • cm FM 5 - 551 <br /> Soluble sulfate content : < 200 PPM FM 5 - 553 <br /> Soluble chloride content < 100 PPM FM 5 - 552 <br /> For walls not using soil reinforcement, use backfill that meets the <br /> following gradation limits determined in accordance with AASHTO T 27 and FM 1 -T 011 : <br /> - 158 - <br /> FPID ( S ) : 423186 - 1 - 58 - 01 <br />