My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2011-226B.1
CBCC
>
Official Documents
>
2010's
>
2011
>
2011-226B.1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/17/2016 2:18:33 PM
Creation date
10/1/2015 3:12:48 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
11/01/2011
Control Number
2011-226B.1
Agenda Item Number
8.N.
Entity Name
Goodson Paving
Subject
Contract and Specifications Old Dixie Sidewalk
Volume II
Area
Old Dixie Highway from 38th Lane to 65th St.
Project Number
0845
Bid Number
2011045
Supplemental fields
SmeadsoftID
10419
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
263
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ell 11 <br /> 4e I <br /> It It tt <br /> r <br /> In the event of an unfavorable comparison between the Resolution test <br /> results and Quality Control test results , make the necessary adjustments to assure that future <br /> comparisons are favorable . <br /> 334-5 . 7 Independent Verification Testing : <br /> 334-5 . 7 . 1 Plant : The Contractor shall provide sample boxes and take samples as <br /> directed by the Engineer for Independent Verification testing. Obtain enough material for three <br /> complete sets of tests (two samples for Independent Verification testing by the Engineer and one <br /> sample for testing by the Contractor) . If agreed upon by both the Engineer and the Contractor, <br /> only one sample for Independent Verification testing by the Engineer may be obtained. <br /> Independent Verification samples will be reheated at the target roadway compaction temperature <br /> for 1 - 1 /2 hours plus or minus 5 minutes, reduced to the appropriate testing size, and conditioned <br /> and tested as described in 334- 5 . 1 . 1 . The Contractor ' s split sample, if tested immediately after <br /> sampling, shall be reduced to the appropriate testing size, and conditioned and tested as <br /> described in 334- 5 . 1 . 1 . If the Contractor ' s sample is not tested immediately after sampling, then <br /> the sample shall be reheated at the target roadway compaction temperature for 1 - 1 /2 hours plus <br /> or minus 5 minutes , reduced to the appropriate testing size , and conditioned and tested as <br /> described in 334- 5 . 1 . 1 . The Contractor ' s test results shall be provided to the Engineer within one <br /> working day from the time the sample was obtained . <br /> If any of the Independent Verification test results do not meet the <br /> requirements of Table 334- 5 , then a comparison of the Independent Verification test results and <br /> the Contractor ' s test results , if available, will be made . If a comparison of the Independent <br /> Verification test results and the Contractor ' s test results meets the precision values of Table 334 - <br /> 6 for the material properties in question, or if the Contractor ' s test results are not available , then <br /> the Independent Verification test results are considered verified and the Contractor shall cease <br /> production of the asphalt mixture until the problem is adequately resolved (to the satisfaction of <br /> the Engineer) , unless it can be demonstrated to the satisfaction of the Engineer that the problem <br /> can immediately be (or already has been) resolved . Address any material represented by the <br /> failing test results in accordance with 334- 5 . 9 . 5 <br /> If a comparison of the Independent Verification test results and the <br /> Contractor ' s test results does not meet the precision values of Table 334 - 6 for the material <br /> properties in question , then the second Independent Verification sample shall be tested by the <br /> Engineer for the material properties in question . If a comparison between the first and second <br /> Independent Verification test results does not meet the precision values of Table 334- 6 for the <br /> material properties in question, then the first Independent Verification test results are considered <br /> unverified for the material properties in question and no action shall be taken. <br /> If a comparison between the first and second Independent Verification test <br /> results meets the precision values of Table 334 -6 for the material properties in question, then the <br /> first Independent Verification sample is considered verified and the Contractor shall cease <br /> production of the asphalt mixture until the problem is adequately resolved (to the satisfaction of <br /> the Engineer) , unless it can be demonstrated to the satisfaction of the Engineer that the problem <br /> can immediately be (or already has been) resolved . Address any material represented by the <br /> failing test results in accordance with 334- 5 . 9 . 5 . <br /> The Engineer has the option to use the Independent Verification sample <br /> for comparison testing as specified in 334 - 6 . <br /> 334-5 . 7. 2 Roadway : Obtain five 6 inch diameter roadway cores within 24 hours <br /> of placement, as directed by the Engineer, for Independent Verification testing . In situations <br /> - 94- <br /> FPID ( S ) : 423186A1 58 -01 <br /> } <br />
The URL can be used to link to this page
Your browser does not support the video tag.