My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2009-280
CBCC
>
Official Documents
>
2000's
>
2009
>
2009-280
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/7/2022 3:11:30 PM
Creation date
10/5/2015 9:04:39 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
11/06/2009
Control Number
2009-280
Agenda Item Number
8.L.
Entity Name
Masci Corporation
Subject
Potable Water Main 77th. Street
Area
77th St.
Project Number
UCP 3086
Bid Number
2009064
Supplemental fields
SmeadsoftID
8783
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
236
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2 <br />3. <br />El <br />assemblies, reinforcement, or side forms. Use only square -faced shovels <br />for hand -spreading and consolidation. Consolidate with care to prevent <br />dislocation of reinforcing, dowels, and joint devices. Do not use vibrators <br />to push or move concrete in forms or chute. <br />Deposit and spread concrete in a continuous operation between <br />transverse joints, as far as possible. If interrupted for more than one-half <br />hour, place a construction joint. <br />Curbs and Gutters: Automatic machine may be used for curb and gutter <br />placement at Contractor's option. If machine placement is to be used, <br />submit revised mix design and laboratory test results which meet or <br />exceed the minimum herein specified. Machine placement must produce <br />curbs and gutters to the required cross-section, lines, grades, finish, <br />and jointing as specified for formed concrete. If results are not <br />acceptable, remove and replace with formed concrete as specified. <br />Joints: Construct expansion, weakened -plane (contraction), and <br />construction joints true -to -line with face perpendicular to surface of the <br />concrete, unless otherwise indicated. Construct transverse joints at right <br />angles to the centerline, unless otherwise indicated. When joining <br />existing structures, place transverse joints to align with previously -placed <br />joints, unless otherwise indicated. <br />a• Weakened -Plane Joints: Provide weakened -plane (contraction) <br />joints sectioning concrete into areas where required. Construct <br />weakened -plane joints for a depth equal to at least one-quarter <br />concrete thickness, by sawing within 24 hours of placement or <br />formed during finishing operations. Place joints at intervals not <br />to exceed 10 feet, if not otherwise indicated. <br />b• Construction Joints: Place construction joints at the end of all <br />pours and at locations where placement operations are stopped <br />for a period of more than one-half hour, except where such pours <br />terminate at expansion joints. Construction joints shall be as <br />shown or, if not shown, use standard metal keyway -section form <br />of appropriate height. <br />C. Expansion Joints: <br />(1) <br />Provide premolded joint filler for expansion joints <br />abutting concrete curbs, <br />catch basin, manholes, inlets, <br />structures, walks, and other fixed objects, <br />unless <br />otherwise indicated. <br />(2) <br />Locate expansion joints at 30 feet o.c. for concrete walks, <br />unless otherwise indicated. <br />(3) <br />Extend joint fillers full width and depth of joint, and not <br />less than one-half inch below finished surface where joint <br />sealer is indicated. If no joint sealer, place top of joint <br />filler flush with finished concrete <br />(4) <br />surface. <br />Furnish joint fillers in one-piece lengths for the full width <br />being placed, wherever possible. Where more than one <br />length is required, lace or clip joint filler sections <br />together. Pieces shorter than four inches <br />shall not- be <br />02576-6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.