My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1974-11
CBCC
>
Ordinances
>
1970'S
>
1974
>
1974-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/19/2019 1:10:18 PM
Creation date
10/5/2015 9:27:48 AM
Metadata
Fields
Template:
Ordinances
Ordinance Number
1974-11
Adopted Date
05/27/1974
Ordinance Type
Regulations
Entity Name
Southern Standard Building Code
Subject
Building Code
Supplemental fields
SmeadsoftID
12407
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
plow <br />V-1, <br />Building Ordinatice continued <br />(3) When application for permit is approved and before a permit <br />is issued, a fee therefor shall be paid as established in a Schedule of <br />Fees by Resolution of the Board of County Commissioners of Indian River <br />County, Florida. <br />Section 22. INSPECTIONS. <br />(1) All new electrical work, and such portions of existing instal- <br />lations as may be affected by new work or any changes, shall be inspected to in- <br />sure compliance with all the requirements of this code and to assure that the in- <br />stallation and construction of the electrical system is in accordance with approved <br />plans. <br />(2) All piping or tubing to be concealed, shall be in place; all junc- <br />tions shall be soldered and left untaped, or approved mechanical connectors may <br />be used. If due to,..structural conditions, panels cannot be set, such adapters <br />shall be in place before meters are installed or system otherwise energized. No <br />such wiring or installation shall be considered ready for inspection until com- <br />pleted as outlined above. <br />(3)* When the electrical work in any building for which a permit has <br />been obtained, is ready for inspection, it shall be the duty of the person in <br />charge of work to give notice in writing on forms furnished at the office of the <br />Building Official, stating the location of the work, name of the owner, name of <br />the person in charge of the work and the name of the -person doing the work. <br />(4) It shall 'be unlawful to lathe, seal or in any manner conceal any <br />electrical wiring or equipment until same has been inspected and approved.. Ser -- <br />vice switch and distribution panel must be set and wired: <br />(5) In large and complicated jobs, the work may be inspected in sec - <br />.tions, on the approval of the Building Official. <br />(G) It shall be unlawful for any person, firm or corporation to use <br />any electric current in or through any wiring apparatus or for light, <br />heat or potrer in any building'or structure subject to this resolution before <br />the same shall have been inspected and approved by the Building Official. <br />(7) The electrical installation or part thereof shall not be cov- <br />ered until it has been inspected, tested and approved as prescribed in this <br />section. If an electrical installation or part thereof is covered before being <br />inspected, tested and approved, it shall be uncovered upon the direction of the <br />-Building Official. <br />Section 23. CERTIFICATE OF P,PPROVAL. <br />.r. <br />(1) Upon the satisfactory completion of the roughing -in inspection, <br />approval shall be so noted on the Electrical Permit Card. This approval shall <br />give the date of the roughing -in inspection and the initials or the inspector. <br />(2) Upon the satisfactory completion and final test of the electrical <br />installation, a certificate of approval shall be issued by the Building Official <br />to be delivered to the owner. <br />1 Section 24: EXISTIMG INSTALLATIONS. <br />(1) If more than Fifty percent (50'!,) of a System that does not con- <br />form to this code is remodeled or altered, the entire system shall be reconstruc- <br />ted to conform to this code. <br />(2) A circuit of an existing system which does not conform to this <br />code shall not be extended or added to until the entire circuit shall have been <br />reconstructed to conform to this coda. <br />Section 25. SERVICE STA'-Df30S. <br />(a) All services sl,all b--2 run in appr'ovc_-d thrn-aded eond1.0t, mini;.uin <br />,r nne a! -,J an. -i el ( 1 1/?) inch ricrdui t to ba ru as a cast thrpuc01 <br />rU'i ui `:i Uri r an;r'oY.'.1 ii O`.).?Ined fl'O;:r tit^_ Cl, Lr 1C Utilit;/ d ;r.rrL- <br />
The URL can be used to link to this page
Your browser does not support the video tag.