My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1991-12
CBCC
>
Ordinances
>
1990'S
>
1991
>
1991-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2019 1:21:55 PM
Creation date
10/5/2015 9:21:18 AM
Metadata
Fields
Template:
Ordinances
Ordinance Number
1991-12
Adopted Date
03/26/1991
Ordinance Type
Building Codes
State Filed Date
04\01\1991
Code Number
Chapter 401
Subject
Building Codes of Title IV
Supplemental fields
SmeadsoftID
12182
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
to, house electrical equipment, telephone equipment, and <br />television equipment which serve the occupants of the entire <br />building. There shallbe —no storage of any kind permitted in <br />this room, <br />(4) Service disconnecting switches must be located in a convenient <br />and readily accessible location inside the building when a <br />meter room is not required. Service disconnecting switches <br />and other related equipment located in enclosed or semi - <br />enclosed porches not exposed to the weather, shall be <br />considered as being located inside the building;Exceptions <br />may be allowed by the electrical inspector on existing <br />installations if strict compliance is deemed by him <br />impractical. <br />(5) A service disconnect shall be located at the nearest point of <br />service entry (conduit not to exceed 20 feet inside building) <br />and shall not be installed in bathrooms, bedrooms, clothes <br />closets, or kitchens cabinets. <br />6) All service equipment of 225 amps or less shall be equipped <br />with a single main disconnect. <br />(T) The grounding electrode conductors shall be a minimum wire <br />size #4 cooper. There shall be a jumper between the hot and <br />cold water pipes above the water heater and before the shutoff <br />valves. The following sharr-also be required: <br />a) All water pipe connections shall be visible. <br />(b) Teardrop or acorn type clamps shall be used at the ground <br />--0d. <br />(c)All clamps shall be of compatible materials (ex. brass or <br />copper). <br />y The ground rod shall be of copper or copper -clad. Note: <br />Galvanized rods may be used on construction temporary <br />service, <br />Section 401.23 Commercial construction <br />The sub -feed to each unit space must provide at least 3 wire, <br />single-phase current, or 4 -wire, 3-phase of 100 ampere capacity. <br />The conduit shall be a minimum 1 1/2 -inch trade size. <br />Section 401.24 General requirements <br />All interior and/or exterior wiring for heat, light, and power <br />in all commercial buildings, schools, churches, theatres, <br />warehouses, and similar locations shall utilize'an approved <br />raceway system. In multifamily residential projects, a <br />(1) <br />11 <br />SmeadSoft Reprint Date: Tuesday, August 20, 2013 - 12:04:52 - OfficialDocuments:610, Attachment Id 0, Page 8 <br />