Laserfiche WebLink
d. FDEP Water Distribution System Construction Permit <br /> The Engineer believes that the relocation of existing water mains within the <br /> project area may require FDEP Permitting. <br /> The Engineer will coordinate review of the plans and design with the Indian <br /> River County Utilities Department (IRCUD) as part of the scope of work. A <br /> separate permit from the IRCUD is not in the scope, as this is a County <br /> directed project. <br /> e. FDOT Project Review Submittal <br /> We will prepare a 90% complete submittal for FDOT administrative and <br /> constructability review of the project. We anticipate responding to the FDOT <br /> comments along with other comments we receive from the 90% review. The <br /> incorporation of these comments will represent the 100% complete drawings. <br /> 12. We anticipate limited drainage calculations may be required for permit items a) <br /> and b) above: The project is anticipated to require minor modification (in kind <br /> realignment due to widening) to roadside swales and the installation, if required, <br /> of side drain pipes under the driveways equivalent to the nearest upstream and <br /> downstream existing side drain. Detailed drainage calculations and basin <br /> analysis to document swale capacity and side drain size are not included for <br /> work proposed on 58th Avenue. For the left turn additions at 69th Street, we will <br /> prepare calculations for submittal to SJRWMD and IRFWCD to demonstrate that <br /> the project meets applicable District Standards. The project is anticipated to <br /> utilize existing stormwater treatment systems within the right of way. This scope <br /> assumes that no new ponds or other significant drainage features will be added. <br /> 13. Engineer will attend up to one meeting during this phase at 90%. Engineer will <br /> prepare agenda and summary meeting notes for each meeting. We will also <br /> perform bi-weekly teleconferences during the course of design. These meetings <br /> and conferences will be used to address issues and to keep the County informed <br /> on progress. No meeting notes will be prepared for the teleconferences. <br /> 14. Engineer will prepare signed and sealed set of Traffic Signal Design (TSD) plans <br /> for the project intersections suitable for bidding and construction. The plans shall <br /> be prepared to FDOT and County standards and shall include luminaires on each <br /> of the structures. <br /> 15. Engineer will prepare signed and sealed set of Signing and Pavement Marking <br /> (S&PM) plans for the project intersections suitable for bidding and construction. <br /> The plans shall be prepared to FDOT and County standards. <br /> 16. Engineer will design and prepare signed and sealed set of proposed road <br /> improvements, anticipated to be, road widening, intersection upgrades, curb and <br /> gutter and sidewalk modifications, surface drainage, ADA upgrades, utility <br /> relocates, and conforms to existing pavement surface. Prepare drawings on 11 <br /> x 17" sheets These sheets will include road, utility and drainage information. <br /> See attached drawing list. <br /> BCG INITIAL CLIENT INITIAL <br /> Page 5 of 14 <br />