My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-059C
CBCC
>
Official Documents
>
2010's
>
2017
>
2017-059C
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/8/2017 10:37:09 AM
Creation date
6/8/2017 10:31:16 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
05/02/2017
Control Number
2017-059C
Agenda Item Number
8.J.
Entity Name
Advanced Roofing Inc.
Subject
Roof Replacement Project for Administration Building
Project Number
1705
Bid Number
2017040
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
337
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1. Where applicable, neatly cut and remove existing stucco to extent indicated in <br />detail drawings and as required to remove existing stucco stop/counterflashing. <br />2. Fabricate counterflashing as shown in detail drawings in 10' lengths. <br />3. Install counterflashing as indicated in detail drawings and secure to receiver <br />flashing 12 inches on center. <br />4. Counterflashing shall extend a minimum of 1.5 inches below base flashing <br />termination. <br />5. Notch and lap ends of adjoining sheet metal sections not less than 4"; apply <br />sealant tape between sections. <br />6. Lap miters at corners a minimum of 1 inch and apply sealant between laps. Rivet <br />at 2" on center. <br />G. Stucco: <br />1. Preparation: <br />a. Protect adjacent Work areas and finish surfaces from damage during <br />stucco application. <br />b. Ensure substrate is sound, clean, dry, and free of dust, dirt, oils, grease, <br />laitance, efflorescence, mildew, fungus, biological residues, chemical <br />contaminants, and other contaminants that could prevent proper <br />adhesion. <br />C. Clean surface to achieve surface . with texture similar to 100 grit <br />sandpaper. <br />d. Sand or grind edge of existing stucco to ensure adhesion and smooth <br />transition to new material. Sand edges to featheredge. <br />e. Use bonding compounds as required by stucco manufacturer and in <br />accordance with ASTM C932 - 06. <br />2. Installation: <br />a. New stucco shall be applied in accordance with ASTM C926 -11a and the <br />manufacturer's guidelines. <br />b. Pre -moisten concrete masonry units prior to the placement of stucco <br />(unless bonding agent has been applied). <br />C. Scratch Coat: apply the stucco with sufficient pressure to ensure intimate <br />contact with substrate and complete coverage to an approximate <br />thickness of '/4 -inch. Score the stucco in preparation for a second coat. <br />Score horizontally. <br />d. Brown Coat: as soon as the first coat is firm enough to receive the second <br />coat without damage, apply the second coat. Alternatively, moist cure the <br />first coat up to 48 hours and dampen the scratched surface with water <br />immediately before applying the second coat. Apply the second coat with <br />sufficient pressure to ensure intimate contact with the first coat to an <br />approximate thickness of '/4 -inch. Use a rod or straight edge to bring the <br />surface to a true, even plane. Fill depressions in plane with stucco. <br />e. After the stucco has lost sufficient moisture so that the surface sheen has <br />disappeared, float the surface lightly with a darby or wood float to <br />densify the surface and to provide a smooth, even surface. Float before <br />the stucco becomes so rigid that it cannot be moved beneath the float. <br />f. Moist cure after the stucco has set by lightly fogging the surface for at <br />least 48 hours. Fog as frequently as required during the 48 hour period to <br />prevent loss of moisture from the stucco. Avoid eroding the ,stucco <br />surface with excess moisture. If relative humidity exceeds 75% the <br />IRC Admin Complex <br />Roof Replacements 07 62 00-7 (Revision No. 1) Sheet Metal Flashing and Trim <br />
The URL can be used to link to this page
Your browser does not support the video tag.