required to provided minimum embedment as required by fastener manufacturer <br /> based upon substrate being secured. Screen for substrate provided by fastener <br /> manufacturer. Corrosion resistant nut and 1-1/2" diameter flat washer. <br /> Acceptable manufacturers include: <br /> a. Hilti Hit Hy-10 Plus <br /> b. Powers Fasteners,Inc.AC 100 Anchoring System <br /> c. ITW Ramset Epcon C6 Fast Curing Epoxy <br /> d. Engineers accepted equivalent <br /> E. Wood to solid concrete substrates: <br /> 1. Masonry screws, 1/4 inch minimum diameter, Type 410 stainless steel with flat <br /> head. Length to provide minimum 1" embedment into substrate. Acceptable <br /> manufacturers include: <br /> a. Tapcon by ITW Buildex, <br /> b. KWIK-CON II by Hilti <br /> c. Powers Fasteners Tapper+ <br /> d. Engineers accepted equivalent. <br /> 2. Sleeve-Type, or Wedge-Type, Expansion Anchor: Minimum 1/2 inch diameter, <br /> Type 304 or 316 Stainless Steel, Expansion Anchor Bolt Assembly of length as <br /> required to provided minimum embedment as required by fastener manufacturer <br /> based upon substrate being secured. Acceptable manufacturers include: <br /> a. Lok/Bolt,Power Bolt or Power-Stud by Powers Fasteners <br /> b. Redi-Bolt,Dynabolt or Trubolt by Red Head Anchoring Systems <br /> c. Kwik Bolt by Hilti <br /> d. Engineers accepted equivalent. <br /> F. Wood to structural steel(greater than 12-GA.): <br /> 1. #12-24 DP5 (for steel thickness up to 1/2") or DP4 (for steel thickness from 1/8" <br /> to 3/8"), flat or hex head,corrosion resistant, self-drilling/self-tapping fastener of <br /> length to provide minimum 3 pitches of thread through metal thicknesses. <br /> Acceptable manufacturers include: <br /> a. ITW Buildex Teks <br /> b. SFS Intec <br /> c. Blazer <br /> d. Engineers accepted equivalent <br /> G. Wood to Grouted Cavity: <br /> 1. Grout: High strength, non-metallic, non-shrink grout for precision grouting and <br /> general construction Conform to ASTM C476 and ASTM C 1107. Acceptable <br /> manufacturers include Commercial Grade Quikrete, Precision Grout, Kauffman <br /> SureGrout or Engineers accepted equivalent. Grout type proportioned by volume <br /> as follows: <br /> a. Portland cement or blended hydraulic cement:one part. <br /> b. Hydrated lime:0 to 1/10 part. <br /> c. Fine aggregate: 2-1/4 to three times sum of volumes of cement and lime <br /> Sebastian Corners Roof Replacement 06 10 00-5 Rough Carpentry <br />