My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018-144B
CBCC
>
Official Documents
>
2010's
>
2018
>
2018-144B
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2018 10:39:24 AM
Creation date
9/10/2018 3:47:07 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
08/14/2018
Control Number
2018-144B
Agenda Item Number
8.Y.
Entity Name
Roof Authority
Subject
Roof Replacement
Area
Sebastian Corners
Project Number
1765
Bid Number
2018062
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
152
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a. Shall be rigid polyisocyanurate roof insulation board with factory applied <br /> coated polymer bondedglass fiber mat facers on the top and bottom. <br /> Boards to comply with ASTM C1289 Type II,Class 2, Grade 2 and meet <br /> the following requirements: <br /> b. Curing time shall be 24 hours minimum, plus an additional 24 hours <br /> minimum per inch thickness, at a minimum of 60 degrees F before <br /> shipment from the manufacturer. <br /> c. Dimensional stability shall be 2 percent maximum linear change when <br /> conditioned at 158 degrees F and 97 percent relative humidity for seven <br /> days. <br /> d. Maximum permissible insulation board size for mechanical attachment is <br /> 4' x 8'. <br /> e. Thickness shall be two layers of 2"insulation. <br /> 2. Tapered Insulation System: <br /> a. Shall be rigid polyisocyanurate roof insulation board with factory applied <br /> coated polymer bonded glass fiber mat facers on the top and bottom. <br /> Boards to comply with ASTM C1289 Type II,Class 2,Grade 2 and meet <br /> the following requirements: <br /> b. Curing time shall be 24 hours minimum, plus an additional 24 hours <br /> minimum per inch thickness, at a minimum of 60 degrees F before <br /> shipment from the manufacturer. <br /> c. Dimensional stability shall be 2 percent maximum linear change when <br /> conditioned at 158 degrees F and 97 percent relative humidity for seven <br /> days. <br /> d. Board size shall be 4 foot by 4 foot. <br /> e. Slope shall be 1/4"per foot and minimum thickness shall be 1/2". <br /> f. Fill Insulation: Shall be rigid polyisocyanurate meeting the above <br /> requirements with board size of 4 foot by 4 foot and thickness of 2". <br /> g. Crickets and Saddles: Shall be rigid polyisocyanurate meeting the above <br /> requirements with a board size of 4 foot by 4 foot and 1/2" per foot <br /> slope. <br /> 3. Cover Board: Shall be cover board approved by roof system manufacturer. <br /> Board Size shall be 4' by 8' and minimum thickness shall be as listed below or as <br /> required by roof system manufacturer. Acceptable products include: <br /> a. Georgia Pacific 1/4"DensDeck Prime Roof Board <br /> B. Insulation Attachment Materials: <br /> 1. Steel Deck Mechanical Fasteners and Stress Plates: <br /> a. Shall be corrosion resistant 3" galvalume stress plate and corrosion <br /> resistant screw type fasteners for use with steel decks; approved by the <br /> insulation manufacturer for the insulation type, thickness and board size <br /> specified; fastener length as required by the fastener manufacturer for the <br /> insulation thickness specified, and to penetrate the deck a minimum of <br /> 3/4 inch and a maximum of 1 inch. <br /> Sebastian Corners Roof Replacement 07 22 16-3 Roof Insulation <br />
The URL can be used to link to this page
Your browser does not support the video tag.