2018-144B
CBCC
>
Official Documents
>
2010's
>
2018
>
2018-144B
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2018 10:39:24 AM
Creation date
9/10/2018 3:47:07 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
08/14/2018
Control Number
2018-144B
Agenda Item Number
8.Y.
Entity Name
Roof Authority
Subject
Roof Replacement
Area
Sebastian Corners
Project Number
1765
Bid Number
2018062
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
152
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PART 3 EXECUTION <br /> 3.01 EXAMINATION <br /> A. Contractor to inspect substrate for soundness and notify Engineer in writing of any <br /> deficiencies. <br /> B. Commencement of work signifies Contractor's acceptance of substrate. Any defects in <br /> roofing work resulting from such accepted substrates shall be corrected to Owner's <br /> satisfaction at no additional expense. <br /> 3.02 PREPARATION <br /> A. General <br /> 1. Roof deck to be dry and broomed clean of debris and foreign matter prior to <br /> installation of insulation system. <br /> 3.03 APPLICATION <br /> A. General <br /> 1. Application shall be in accordance with the insulation/membrane manufacturer's <br /> instructions and these specifications. <br /> 2. All insulation to be in full sheets, carefully fitted and pushed against adjoining <br /> sheets to form tight joints. Gaps exceeding 1/4 inch will not be accepted. <br /> 3. Insulation and overlayment boards that must be cut to fit shall be saw cut or <br /> knife-cut in a straight line,not broken. Chalk lines shall be used to cut insulation. <br /> Uneven or broken edges are not acceptable. <br /> 4. Remove insulation dust and debris that develops during insulation cutting <br /> operations. <br /> 5. Joints between successive and adjacent layers of insulation to be offset a <br /> minimum of six(6")inches. <br /> 6. Stagger joints of gypsum overlayment/overlayment insulation one (1') foot <br /> (vertically and laterally)to ensure that joints do not coincide with joints from the <br /> previous or adjacent layer. <br /> 7. On steel decks, apply insulation boards with long dimension of units across deck <br /> ribs. Ends of insulation boards must be bearing on top flange of steel deck. <br /> 8. Crickets,saddles and tapered edge strips shall be installed before the overlayment <br /> insulation. <br /> 9. Adhere tapered edge strips at transitions, terminations and/or penetrations as <br /> detailed or required in ribbons of foam adhesive to ensure smooth transitions are <br /> provided for the roof membrane and flashings. <br /> 10. Provide necessary modifications to insulation system or nailers at roof edges as <br /> required to ensure a flush and smooth transition is provided for the roof <br /> membrane and flashing. <br /> 11. Field modifications of insulation,tapered insulation,tapered edge strips and cants <br /> shall be made by the Contractor where required to accommodate roof and <br /> flashing conditions, prevent water dams and ponding water. Ponding water at <br /> scuppers and cricket valleys shall not be accepted. <br /> 12. Provide necessary modifications to prevent standing water which is defined as <br /> 1/4" of water in a 4-square foot or larger area 24 hours or more after <br /> precipitation. <br /> Sebastian Corners Roof Replacement 07 22 16-4 Roof Insulation <br />