Laserfiche WebLink
IRC-1838 Indian River County <br />Main Library <br />Roof Replacement 07 71 19-3 Manufactured Gravel Stops and Fascias <br />b. Aluminum Finish: <br />i. Standard color Kynar-500 as selected by the Architect from roof <br />edge manufacturer's color chart. <br />c. Fascia: Standard 12 feet 0 inches (3.65 m) lengths. <br />d. Extruded bar: Shall be continuous 6063-T6 alloy aluminum at 12 feet 0 <br />inches (3.65 m) standard lengths with pre-punched slotted holes. All bar <br />miters are welded. <br />i. Injection Molded EPDM Bar Splice to allow thermal movement <br />expansion of extruded aluminum anchor bar. <br />ii. Fasteners: 2 inch (51 mm) stainless steel with driver. <br />e. Model as required to meet field conditions and Contract Drawings. <br />f. Performance: <br />i. Lifetime, 215 mph Wind Warranty. <br />ii. Tested per ANSI/SPRI ES-1 Standard to a design pressure of 290 <br />lbs./ft2to comply with the International Building Code. <br />iii. Factory Mutual 1-645 approved for wind up lift protection. <br />iv. Miami-Dade Approved (No. 19-0430.02 12/11/23) to comply with <br />the "High Velocity Hurricane Zone of the Florida Building Code". <br />2.3 ACCESSORIES: <br />A. Corners, end caps, fascia sumps, or spillouts, etc. shall be fabricated by the roof edging <br />manufacturer. Factory fabricated mitered corners shall have 12” nominal leg lengths. <br />B. Provide matching ledgecaps, downspouts, or other special fabrications as detailed. <br /> EXECUTION <br />3.1 EXAMINATION <br />A. Verify that the roof edging installation will not disrupt other trades. Verify that the substrate <br />is dry, clean and free of foreign matter. Report and correct defects prior to any installation. <br />3.2 INSTALLATION <br />A. Submit design drawings for review and approval to Engineer before fabrication. <br />B. Installing contractor shall check as-built conditions and verify the manufacturer’s roof <br />edging details for accuracy to fit the wall assembly prior to fabrication. The installer shall <br />comply with the roof edging manufacturer’s installation guide when setting edging. <br />C. Installer shall use stainless steel screw type fasteners as provided by manufacturer, <br />nominal 1-1/4” length, with minimum 240 lb. pull-out resistance; suitable for the substrates <br />to which being installed. <br />D. Install waterproof sealant to underside of retainer base plate as recommended and suppled <br />by the roofing membrane manufacturer. <br />END OF SECTION 07 71 19