Subject
Work Order No. 7 at Hobart Reverse Osmosis Water Treatment Plant
Supervisory Control and Data Acquisition (SCADA) System Upgrades
Bid Number
RFQ2019070
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Consultant will remove DHRIO modules from the configuration and perform <br />PLC panel completion. <br />Contractor will perform a radio survey to provide ethernet radio connectivity <br />from North Beach to the WTP. <br />Contractor will upgrade RIO racks and work with Consultant to upgrade North <br />Beach to CompactLogix PLC. <br />Consultant will install a new L72 PLC in the main PLC panel at a later version of <br />Studio 5000 to be determined. <br />The existing warm back up rack will be either removed or have a second L72 <br />CPU installed. <br />Consultant will provide any further programming on various systems, startup all <br />systems together and finalize the entire system. <br />Consultant will replace Rotork Pakscan communication network. Contractor will <br />install option cards in all of the Rotork actuators which will allow the valves to <br />be controlled via a 4-20ma signal. Contractor and Consultant will add any <br />additional analog I/O, if needed, and CSD will modify the PLC program to use <br />analog I/O for control. Consultant will make any updates needed in the <br />VTScada database. Consultant will test and verify functionality. <br />Consultant will revamp the Lime Slurry panel PLC from the existing MicroLogix <br />to ControlLogix remote I/O and incorporate into the main PLC program. <br />Consultant will test and verify operation. <br />SCHEDULE <br />In general, the following schedule is anticipated and consultant will work as <br />expeditiously as possible to meet it: <br />Task 1: 8 -10 months after Contractor awarded project <br />Task 2: To occur concurrent to Task 1 <br />K:\WPB_Civil\General\Black\Florida\IRCU\Hobart PLC\20211118 - Scope - Hobart PLC Construction.docx Page 3 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.