My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1968-009
CBCC
>
Resolutions
>
1960's
>
1968
>
1968-009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/22/2022 11:00:17 AM
Creation date
4/22/2022 10:57:07 AM
Metadata
Fields
Template:
Resolutions
Resolution Number
1968-009
Approved Date
02/21/1968
Resolution Type
Adopting a Building Code
Subject
Adopting Building Code, Electrical & Plumbing Codes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
and must be controlled by wall switches only. <br />(u) For protection against rust nr corrosion, all steel or <br />iron outlet boxes, junction boxes, cabinets, gutters, and similar type <br />equipment subject to rust or corrosion, shall be protected with a <br />zinc or cadmium coating by either the galvanizing or sherardizing <br />process. <br />(v) Wiring of slim line or end to end fixtures shall be as <br />follows: Asbestos .l, 000 volt No. 14 wire or itlal No. .12 wire will be <br />accepted for circuit wiring of fixtures that are installed end to end, <br />to the extent of the supply of that circuit passing through fixture that <br />it supplies. The only permitted use of the fixture as a raceway would <br />be for those fixtures approved by the Underwriters for that purpose; <br />with special raceways, and lil i No, i2 wiring would be accepted for <br />additional circuits when installed according to this approval. <br />Cas and oil burning equipment- Each unit shall be on a separ- <br />ate circuit and be provided with a pilot light, and switch located near <br />the entrance to the room where unit is installed. Minimum wire size <br />No. 12 or larger. <br />(w) Swimming pools; All conduits, junction boxes, reinforcing <br />steel, filter pump equipment, lighting fixtures and sinillar metallic <br />equipment must be bonded together and connected to a common ground. <br />Metallic parts of ladders and diving boards must also be grounded. <br />All underwater pool lights must be of approved low voltage type. <br />Section 28. F l:i✓DERS. The carrying capacity of each feeder <br />or subfeeder shall he based on the number of separate circuits which <br />it supplies, computed as follows: <br />(1) Overhead lighting circuits --assumed as having 1,000 watts <br />per circuit for each 15 -amp. circuit. <br />(2) Convenience outlet circuits --assumed as having 1, 000 watts <br />per circuit. <br />(3) Non -itemized and heavy duty circuit--spceified load for <br />which designed. <br />29 <br />
The URL can be used to link to this page
Your browser does not support the video tag.