Laserfiche WebLink
Furnish, install, splice, and test all fiber optic cable, fiber optic assemblies, patch cords, and all <br />passive network infrastructures including, but is not limited to, splice trays and closures, patch <br />panels, fan -outs, terminations, and fusion splices. <br />Furnish all tools, equipment, materials, supplies, and manufactured articles, and perform all <br />operations and equipment integration necessary to provide a complete, fully operational passive <br />fiber optic infrastructure. <br />The necessary equipment shall be the responsibility of the Contractor. Provide all labor and <br />equipment necessary to move inventory and to transport it to the installation location. Install all <br />items in accordance with the manufacturer's instructions or as directed by the Owner. <br />7.5.2 Fiber Optic Cable Specifications <br />The following table presents the optical requirements of the single mode and multimode fiber: <br />Parameters <br />Single Mode <br />Multi <br />Type <br />Step Index <br />Graded Index <br />Core Diameter <br />8.3 gm Nominal <br />50 prn <br />Cladding Diameter <br />125 pm <br />125 m <br />Core to Cladding Offset <br />:50.8 lim <br />151.5 pm <br />Coating Diameter OSP <br />245 pm <br />245 lim +/-5 Vm <br />Coating Diameter (IP) <br />900 pm ±15 pm <br />Cladding — circularity <br /><_ 0.7% <br />Proof Tensile Test <br />100 k si 0.7 GN/M2) <br />Attenuation <br />@850 nm MM <br />N/A <br /><_ 3.5 dB/km <br />@1300 nm (MM) <br />N/A <br /><_ 1.0 dB/km <br />@1310 nm SM <br /><_ 0.4 dB/km <br />N/A <br />@1550 nm SM <br /><_ 0.3 dB/km <br />N/A <br />Bandwidth <br />@850 nm MM <br />N/A <br />200 <br />@1300 nm (MM) <br />N/A <br />1000 <br />Chromatic Dispersion <br />Zero Dispersion <br />1301.5/1321.5 nm <br />Wavelength Zero <br />Dispersion Slope <br />0.089 ps/nmz - km <br />Maximum Dispersion <br />3.3 ps/(nm*km) for 1285-1330 <br />nm <18 s/ nm km for 1550 nm <br />Cut — Off Wavelength <br />1260 nm <br />Numerical Aperture <br />(EIA — 455 — 47) <br />NA <br />0.275 <br />All optical fibers shall be proof tested by the fiber manufacturer at a minimum load of 100 kpsi. <br />All optical fibers shall be 100% attenuation tested at the factory for compliance with performance <br />specifications described herein. The attenuation data for each fiber shall be provided with each <br />cable reel. <br />7.5.3 Fiber Optic Cable Outside Plant (OSP) <br />Provide outside plant cable (OSP) suitable for installation in an underground conduit <br />environment including constant immersion in water for outdoor installations. The cable shall be <br />provided and installed in continuous links. Fibers in the fiber optic cable shall be spliced and/or <br />terminated as specified by the Owner project supervisor. <br />28 <br />