My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2023-193
CBCC
>
Official Documents
>
2020's
>
2023
>
2023-193
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/9/2023 1:24:47 PM
Creation date
10/9/2023 1:21:41 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Agreement
Approved Date
09/12/2023
Control Number
2023-193
Agenda Item Number
8.K.
Entity Name
Precision Contracting Services, Inc.
Subject
Agreement for Annual Fiber Optic Engineering, Design Material, Supplies, and Installation
Area
Various throughout Indian River County
Bid Number
2023056
Document Relationships
2023-194
(Cover Page)
Path:
\Official Documents\2020's\2023
2023-195
(Cover Page)
Path:
\Official Documents\2020's\2023
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1. Primary surge suppression shall consist of a wall or flush mounted unit with 12 AWG <br />terminals with a maximum 80kA (8/209s), protecting lines L -N, L -G, L -L, and N -G. The <br />unit shall meet the following environmental requirements: ambient temperatures of - <br />409F to 1859F (409C to 852C working) and 95% RH (non -condensing). Dimensions shall <br />be 4.5" x 2.9" x 2.3". <br />2. A nine -outlet (seven switched, two un -switched) rack mounted surge suppressor unit <br />shall be installed. The maximum surge current shall be 84kA with a load current of <br />15A or 20A, at a working voltage of 120V 50/60Hz. <br />3. A 19" DIN Rail kit assembly shall be installed and have enough space for 32 modular <br />surge suppressor devices (RJ11, RJ45, or BNC connector type) attached, meeting the <br />following criteria: ambient temperature of -402F to 1852F (-209C to 859C working) <br />and 95% RH (non -condensing). Dimensions shall be 5.04"H x .99"W x 2.25"D. <br />h) Common Grounding System: A floor mounted 12 -position ground bar shall be provided <br />with the cabinet. <br />i) Cabinet Construction: <br />1. The cabinet shall contain R-4 insulation to control the effect of environmental <br />conditions. <br />2. Cabinet shall be of 1/8", 5052 Aluminum construction with white powder coat finish to <br />eliminate rusting. <br />3. Doors shall have NEMA 311 rated with neoprene gasketing, for maximum equipment <br />protection, and shall have heavy-duty 3 -point hardware on all doors. <br />4. All hinges shall be 1/8" aluminum with a stainless steel piano hinge, or continuous door <br />length stainless steel hinges. <br />7.9.3 Field Device Cabinet Type III (332 Special) <br />Install field device cabinet that provides an environmentally secure enclosure to house ITS field device <br />equipment, subsystems and systems, lighting and surge protection. The cabinet shall be designed for the <br />explicit use of housing and protecting sensitive electronic equipment (Encoders, 10/100/1000 Ethernet <br />switches, media converters, port/terminal servers, fiber optics equipment, and other related <br />components, etc.) within a controlled environment necessary for the proper operation of installed <br />electronic equipment. <br />The detector cabinet shall meet or exceed the following minimum requirements: <br />a) Size: Outside dimensions shall be approximately 66"H x 24"W x 30"D; <br />b) Lighting: The cabinet shall include door activated 20W cool white fluorescent lights; <br />c) Electrical Outlets: One duplex (GFI) receptacle shall be included with every cabinet; <br />d) Equipment Racks: One 19" equipment rack, adjustable 4 -post design, with 5/8" - 5/8" — <br />1/2" spacing with holes tapped for #12-24 screws, a rack -mounted drawer shall be <br />included with the rack; <br />e) Air Filtration: The cabinet shall contain a filtered air intake vent featuring re -usable, <br />washable type filters; <br />f) Power Distribution: The 30A main breaker provided in the cabinet shall distribute power <br />to rack mounted equipment, lighting, and outlets; <br />g) Surge Protection: <br />1. Primary surge suppression shall consist of a wall or flush mounted unit with 12 AWG <br />terminals with a maximum 80kA (8/209s), protecting lines L -N, L -G, L -L, and N -G. The <br />unit shall meet the following environmental requirements: ambient temperatures of - <br />409F to 1859F (-409C to 859C working) and 95% RH (non -condensing). Dimensions shall <br />be 4.5"H x 2.9"W x 2.3"D. <br />37 <br />