Laserfiche WebLink
XV. Microwave Terminal Alarms/ SPARCS NMS Alarms <br />Test <br />Description <br />A TRUE COPY <br />CERTIFICATION ON LAST PAGE <br />RYAN L. BUTLER, CLERK <br />The purpose of this test is to demonstrate that both the EM2 software and the external LED's display Minor <br />and Major alarms. Also test the function of the Network Management software and ensure alarm reporting <br />is working properly during this test. <br />Instructions <br />Begin by ensuring that no alarms exist on the terminal to be tested. If any alarms are present troubleshoot <br />those alarms and then continue with the test. <br />1. Log on to the Terminal under test if you have not already logged on. <br />a. Connect a PC with the EM2 software installed via the serial connector on the front of the <br />terminal labeled "COMPUTER" <br />a. Open the EM2 software and on the initial log -in screen select "Serial" from the pull down and <br />choose the appropriate "COM PORT" that the PC is using. <br />b. Enter the username: "Admin" (note this cannot be changed) enter the password. The default <br />password is "password" which can be changed). Once the correct "Admin" and "User <br />Password" is entered you will be "logged on" and the displayed terminal icons will go from <br />gray to blue to indicate communication with the terminal under test. <br />2. This test will also include the SPARCS NMS alarm monitoring features. <br />a. Ensure the Network Manager is online and able to see all radios being tested. <br />b. b. On the bottom portion of the screen ensure the "Current" alarms window is visible. <br />c. All network icons on the right hand "Map" side should be "Green" at the start of the test. <br />3. 3.In the local EM2 software, go to the "Status" and then "Link Alarms" screen. This will show the <br />presence of alarms for all terminals on the hop being tested. <br />4. Cause a MINOR alarm by removing the SIM card. The minor alarm should show up in both the EM2 <br />alarms as well as the SPARCS NMS <br />5. Return the SIM card to the normal operating position and all alarms should clear except the Severity <br />Section of the Link Alarm screen. It holds the color of the highest alarm until reset. Also the "Latched" <br />alarms will show on the main screen as a blue indicator until latched alarms are reset. <br />6. Once all the alarms have cleared click on the "RESET" button in the EM2 "Link Alarms" section to <br />clear out latched alarm indications. <br />7. Now a Major alarm is to be tested by setting the RFU to a Mute state. <br />8. 8.Go to the "Test" menu on the EM2 software and select "RFU Mute" then click the button for the RFU <br />TX Mute State so it says "MUTED" and click the Apply button. <br />9. Monitor the external LED, the internal Link Alarm screen, and the SPARCS NMS alarms for a Major <br />alarm. <br />10. Return the radio to the normal operations and watch to ensure that all alarms clear. <br />11. Pull DC Power from the SPU to be tested and ensure the alarms on the far end and SPARCS are <br />Page 31 of <br />