My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2004-138
CBCC
>
Official Documents
>
2000's
>
2004
>
2004-138
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/1/2016 2:05:06 PM
Creation date
9/30/2015 7:37:13 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
06/15/2004
Control Number
2004-138
Agenda Item Number
7.G.
Entity Name
Timothy Rose Contracting
Subject
Discharge Outlet and Rip Rap Spillway Mat
Contract and Specifications
Area
North County
Project Number
2208
Bid Number
6069
Archived Roll/Disk#
3210
Supplemental fields
SmeadsoftID
3827
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
185
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S . Good alignment g ent shall be preserved during installation . The deflection at <br /> joints shall not exceed that recommended by manufacturer. Fittings , in <br /> addition to those shown on the Drawings , shall be provided , if required , in <br /> crossing utilities which may be encountered upon opening the trench . <br /> T. Each length of the pipe shall have the assembly mark aligned with the <br /> pipe previously laid and held securely until enough backfill has been <br /> placed to hold the pipe in place . Joints shall not be " pulled " or " cramped . " <br /> U . Before any joint is made , the pipe shall be checked to assure that a close <br /> joint with the next adjoining pipe has been maintained and that the inverts <br /> are matched and conform to the required grade . The pipe shall not be <br /> driven down to grade by striking it. <br /> V. Precautions shall be taken to prevent flotation of the pipe in the trench . <br /> W . When moveable trench bracing such as trench boxes <br /> moveable <br /> sheeting , shoring or plates are used to support the sides of the trench , <br /> care shall be take in placing and moving the boxes or supporting bracing <br /> to prevent movement of the pipe , or disturbance of the pipe bedding and <br /> the backfill . Trench boxes , moveable sheeting , shoring or plates shall not <br /> be allowed to extend below the top of the pipe . As trench boxes , <br /> moveable sheeting , shoring or plates are moved , pipe bedding shall be <br /> placed to fill any voids created and the backfill shall be recompacted to <br /> provide uniform side support for the pipe . <br /> X . Concrete thrust blocks shall be installed at all fittings and other locations <br /> as directed by the Engineer. Minimum bearing area shall be as shown on <br /> the Drawings . Concrete shall be placed against undisturbed material and <br /> shall not cover joints , bolts or nuts , or Interfere with the removal of any <br /> joint. Wooden side forms shall be provided for thrust blocks . <br /> Y. Restrained joints shall be installed where shown on the Drawings or as <br /> directed by the Engineer. <br /> 1009 TESTING <br /> A. All PE water mains shall be field -tested . Supply all labor, equipment, <br /> material , gages , pumps , meters and incidentals required for testing . <br /> Pressure test each water main upon completion of the pipe laying and <br /> backfilling operations , including placement of any required temporary <br /> roadway surfacing . <br /> B . All water mains shall be tested at 150 percent of the operating design <br /> pressure of the pipe unless otherwise approved by the Engineer. The <br /> operating design pressure of the pipe is 100 psi . The test pressure shall <br /> be measured at the highest point along the test section by a recording <br /> type pressure gage and a copy of the readout shall be submitted to the <br /> Engineer upon completion of the test. All testing shall be conducted in <br /> the presence of the Engineer or his/her designated representative . <br /> ' 0262777 <br /> FAUtilities\UTILITY - ENGINEERING\WTP - North RO\N RO Brine Line Discharge - UCP#2208\BID DOCUMENTS North County <br /> ' RO\BID DOCUMENTS\02627 Water Mains High Density Ployethylene.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.