My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2007-245
CBCC
>
Official Documents
>
2000's
>
2007
>
2007-245
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/3/2016 10:24:14 AM
Creation date
9/30/2015 11:00:21 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Second Amendment
Approved Date
07/24/2007
Control Number
2007-245
Agenda Item Number
11.I.2
Entity Name
McMahon Associates, Inc.
Subject
Amendment No.2 Intersection Improvements
Area
CR-510 and U. S. Highway 1
Supplemental fields
SmeadsoftID
6425
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 . Lighting Plans: Note, a lighting design was included in the original agreement; however, it <br /> was assumed that only relocations would be necessary. This supplement (number 2) addresses <br /> only the differences in the preparation of the design/plans due to the widening, and what was <br /> not included in the FDOT RRR project. <br /> The Lighting Plans will include the following: <br /> a. Key Sheet <br /> b. Summary of Pay Item for Estimates <br /> c. Tabulation of Quantities <br /> d. General Notices/Pay Item Notes <br /> e. Pole Data/Legend & Criteria <br /> f Service Point Details <br /> g. Project Layout <br /> h . Plan Sheets <br /> i. Special Details <br /> 2. Lighting Report/Voltage Drop Calculations <br /> A Lighting Report will be prepared and submitted, including voltage drop calculations <br /> showing the equation or equations used along with the number of luminaries per circuit, the <br /> length of each circuit, the size conductor or conductors used and their ohm resistance values. <br /> The voltage drop incurred on each circuit (total volts and percentage of drop) will be <br /> calculated. <br /> Load analysis calculations shall be submitted for each branch circuit breaker and main <br /> breaker. <br /> 3 . Coordination with Utilities <br /> The lighting design will be coordinated with the maintaining agency and any utility owners <br /> affected by the lighting project. <br /> K. Utility Design <br /> L Utility Subsurface Locates <br /> The ENGINEER will locate horizontally and vertically subsurface utilities, only for those <br /> utilities owned and operated by Indian River County, at conflicts with the proposed storm <br /> sewer facilities and proposed signalization mast arms. Additional design services will include <br /> the following tasks: <br /> 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.