My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2007-351
CBCC
>
Official Documents
>
2000's
>
2007
>
2007-351
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/27/2016 1:18:27 PM
Creation date
9/30/2015 11:22:51 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Third Amendment
Approved Date
10/16/2007
Control Number
2007-351
Agenda Item Number
7.G.
Entity Name
McMahon Associates,Inc.
Subject
Amendment No.3 Intersection Improvements
Area
CR-510 and US Highway 1
Supplemental fields
SmeadsoftID
6645
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
221 +00, as referenced from the baseline of construction for 58'" Ave., and from Station <br /> 750+00 to Station 767+87.50 as referenced from the baseline of construction for SR-5 (US- 1 ). <br /> Additional design services will include the following tasks: <br /> a. Perform the horizontal and vertical location design of the proposed 8-inch water main and <br /> 6-inch sanitary sewer force main stub-outs at approximately 1 ,000 foot intervals from <br /> Station 281 +26.74 to Station 362+58.28, as referenced from the baseline of construction <br /> for CR-510, from Station 204+40 to Station 221 +00, as referenced from the baseline of <br /> construction for 58'" Ave., and from Station 750+00 to Station 767+87.50, as referenced <br /> from the baseline of construction for SR-5 (US- 1 ). Stub-outs will be designed to extend <br /> beyond both sides of the proposed roadway. Connections to the existing mains will be <br /> proposed to be made via wet tapping methods. <br /> b. The ENGINEER shall identify potential utility conflicts. The existing utilities at these <br /> conflict points will be located vertically and horizontally, as discussed in the Utility <br /> Subsurface Locates item #4 below. This information will be used for design purposes to <br /> provide the minimum vertical clearances, as required by the Department of <br /> Environmental Protection. <br /> c. The ENGINEER shall prepare Utility Improvement Plan and Profile Sheets at a F'=40' <br /> scale to show location of the proposed stub-outs. Note: The Utility Improvement Plans <br /> will also be used to show all other existing utility adjustments and proposed utility <br /> additions. <br /> d. The ENGINEER will coordinate with utility owners to minimize relocations. <br /> e. The ENGINEER will prepare FDEP permit application "Notice of Intent to use the <br /> General Permit for Construction of Water Main Extensions for PWSs" and support data <br /> for signature by the COUNTY, and submit package to FDEP for processing. <br /> f The ENGINEER will prepare FDEP permit application "Notification/Application for <br /> Constructing a Domestic Wastewater Collection/Transmission System" and support data <br /> for signature by the COUNTY and submit package to FDEP for processing. <br /> g. The ENGINEER will process Request for Information (RFI) comments from FDEP one <br /> time for each permit application and provide additional data as requested with assistance <br /> from the COUNTY, as required. <br /> h. Permit application fees are not included and shall be paid by the COUNTY. <br /> i . It is assumed that the proposed reclaimed water mains will not be adding any additional <br /> users to this main at this time (an additional user is utilizing 100,000 gpd or more of <br /> reclaimed water). Therefore, FDEP permit applications for the reclaimed water mains are <br /> not included as part of this scope of work. <br /> 5 <br />