2007-259(a-b)
CBCC
>
Official Documents
>
2000's
>
2007
>
2007-259(a-b)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/14/2016 10:18:20 AM
Creation date
9/30/2015 11:01:50 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Certificate
Approved Date
07/26/2007
Control Number
2007-259(a-b)
Agenda Item Number
county administrator signature
Entity Name
Turner Construction
Subject
IRC Emergency Operations Center - Punch List
Area
4225 43rd Ave.
Project Number
5054.18
Supplemental fields
SmeadsoftID
6484
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Indian River County Emergency Operations Center <br /> Interior Punch List - Tuesday - 06/ 12/07 <br /> June 22, 2007 <br /> Page 9 <br /> ESF-19 - Room 010 (continued) <br /> 14. Drywall to the right of Door frame 012, where it abuts the hollow metal frame needs to be sanded and <br /> repainted, irregular. Also, the outside corner between Door 012 & 013 above the vinyl base needs to be <br /> sanded and repainted, very irregular. <br /> 15 . Drywall above door frame 013 and 012 needs to be repainted, brush marks are showing. Also, to the top left <br /> of door frame 103 a mark on the drywall needs to be repainted and fingerprints above Door 012 need to be <br /> repainted on the drywall above the right and left corner of Door 012. <br /> 16. Drywall around the Johnson Control to the right of Door 013 is irregular, needs to be sanded and repainted <br /> and also to the right of this the inside corner is irregular needs to be sanded, caulked and repainted . <br /> 17. Bottom left of hollow metal Door 014 drywall is irregular approximately 3ft. off the floor and above the vinyl <br /> base in this same area. Needs to be sanded and repainted. <br /> 18. Drywall to the right of Door 014 between the hollow metal frame and inside corner this area needs to be <br /> sanded and repainted. <br /> 19. West wall to the left of door 014, outside corner is very irregular needs to be sanded and repainted and also <br /> above the vinyl base in this same area drywall is irregular needs to be sanded and repainted. <br /> 20. Drywall to the left of hollow metal door frame 016 needs to be sanded and repainted where it abuts the hollow <br /> metal frame and also fingerprints in this same area. <br /> 21 . To right of door frame 016, approximately 5ft up on the wall marks on the drywall need to be repainted. <br /> 22 . Ceiling grid, I st ceiling grid off the north wall is dirty, needs to be replaced or cleaned the complete length of <br /> the corridor. <br /> 23 . Inside corner at the drywall header as you are coming off the Multi-Purpose Room 005 , grid is irregular, this <br /> needs to be repaired. <br /> ESF-15 - Room 012 <br /> 1 . Outside face of Door 012 needs to be cleaned of glue and drywall mud. <br /> 2. Hollow metal frame needs to be touched-up with paint where it has been scuffed on the inside and outside <br /> edges. <br /> 3 . Bottom right of edge of hollow metal frame just above the vinyl base needs to be repainted. <br /> 4. Drywall to the left of hollow metal door 012, left of the bottom hinge needs to be sanded and repainted. That <br /> is also true to the left of the middle hinge. <br /> 5. Hollow metal door frames need to be sanded and repainted above the top hinge and to the left of the closure. <br /> paint over-runs. <br /> 6. Drywall at the top right of Door 012, paint finish is irregular needs to he sanded and repainted. <br /> 7. West wall bottom left electrical outlet irregularity in the drywall needs to be sanded and repainted . <br /> 8. Right hand side corner on the left wall inside corner and drywall on the north wall is irregular, needs to be <br /> sanded and repainted. <br /> 9. North wall drywall around the electrical outlet needs to be patched and repaired, opening cut too large and <br /> also to the top right and right to Data Outlet 27/28D marks on the drywall the complete length of the wall <br /> from the data outlet to the right inside corner. <br /> 10. Electrical outlet on the east wall drywall needs to be sanded and painted. Drywall is irregular. <br /> It . South wall drywall around electrical outlet adjacent to TV Outlet 29 outlet cover needs to be set flush to the <br /> drywall . <br /> 12. South wall to the left of the electrical outlet and door stop drywall is irregular needs to be sanded and <br /> repainted. <br /> 13 . One ceiling tile missing. <br /> D O N A D I O <br /> & Associates , Architects. P.A . <br />