Laserfiche WebLink
Indian River County Emergency Operations Center <br /> Interior Punch List - Friday - 06/15/07 <br /> June 22, 2007 <br /> Page 12 <br /> Corridor 036 (continued) <br /> 5 . Drywall to the right of Door 038, approximately 6ft. above the vinyl base, dent in the drywall and the patched <br /> area is unacceptable and also on the scuff marks on the vinyl base. <br /> 6. About the center of the wall between Door 038 and 039 marks on the drywall needs to be repainted. <br /> 7 . To the left of Door 039 drywall above the vinyl base needs to be sanded and repainted. <br /> 8. Drywall above Door 039, where it abuts the hollow metal frame, needs to be sanded and repainted. <br /> 9. To the right of Door 039, drywall where it abuts the hollow metal frame from floor to top of frame needs to be <br /> sanded and repainted. Irregular. <br /> 10. Door 040 is damaged on the right and left jambs and at the head and the top right corner. <br /> 11 . Drywall to the left of Door 041 needs to be sanded and repainted where it abuts the hollow metal frame. <br /> Also, above this door marks on the wall need to be cleaned and repainted . <br /> 12 . Ceiling tile directly to the top right of Door 040 and to the left of light fixture, chip in the tile and marks on <br /> the grid . <br /> 13 . Bottom right of Door 041 where drywall abuts the hollow metal frame needs to be sanded and repainted. <br /> 14. Lens cover missing on light fixture and to the south of Corridor 046 adjacent to the Exit light. <br /> 15. Top right of Door 043 marks on the drywall need to be cleaned and repainted and also to the right of top of <br /> the door frame 043 irregularity in the drywall needs to be sanded and repainted . <br /> 16. Exterior Door 036, frame for weather stripping needs to be cleaned of paint and set flush to the frame. <br /> 17 . Left and right outside corners of the drywall at Door 036, needs to be sanded and repainted. <br /> 18 . Drywall between Doors 040 & 050, spots on the drywall and dirt marks etc, the whole length needs to be <br /> sanded and repainted in numerous areas . <br /> 19. Bottom right and to left of Door 045 frame is damaged. <br /> 20. East wall to the right of Corridor of 046 and in between Corridor 046 and electrical outlet, irregularities in the <br /> drywall from the floor up approximately 30 inches need to be sanded and repainted . That is also true to the <br /> right of this electrical outlet approximately 6ft plus or minus . <br /> 21 . Drywall at the east wall numerous areas the length of this wall to the south of 046 scratches in the paint from <br /> roller, fingerprints, etc . this need to be redone. <br /> 22. Vinyl base scuff marks to the left of Door 037 , approximately loft. in length . <br /> 23 . Ceiling grid is bent the ceiling gird in front of the 2nd light fixture to the north of the south wall of Corridor <br /> 036. <br /> 24. The ceiling tile to the south of the light fixture in front of Door 041 is damaged. <br /> Corridor 046 <br /> 1 . Ceiling grid at the intersection of Corridor 046 & 036 is bent. <br /> 2. Ceiling tile in front of the opening of Office Area 058 & 062, fingerprints on the ceiling tile. <br /> 3 . The outside comer of the south wall at the intersection of Corridor 051 & 046 at Vestibule 057, needs to be <br /> sanded and repainted. <br /> 4. Drywall to the left of Corridor 051 , between Corridor 051 and Door 069 approximately 4-5ft. in, in that <br /> comer and approximately 2-3fr. off the floor, drywall is irregular, pencil marks , glue, etc. this area needs to be <br /> cleaned, sanded and repainted. <br /> 5. Center of the wall between Corridor 051 and 069 approximately 2ft. up, irregularity in the drywall needs to be <br /> sanded and repainted. <br /> 6. Drywall above Door 069 needs to be cleaned of fingerprints and painted. <br /> 7 . Drywall to the bottom right and left of Door 069 needs to be sanded and repainted . <br /> 8 . The northeast outside corner at the intersection Corridor 036 & 046 needs to be sanded and repainted. Also, <br /> in this area approximately 5fr. of vinyl base is scuffed, needs to be cleaned. <br /> 9. Edges of the drywall opening leading into Office Area 052 and 068 needs to be sanded and patched and <br /> repainted. <br /> D O N A D I O <br /> & Associates, Architects, P.A. <br />