Indian River County Emergency Operations Center <br /> Interior Punch List - Friday - 06/15/07 <br /> June 22, 2007 <br /> Page 13 <br /> Corridor 046 (continued) <br /> 10. Paint finish in this area fingerprints, roller overlaps, etc., the length of the wall , this needs to be discussed with <br /> the Contractor. <br /> Corridor 051 <br /> 1 . West wall, outside corner of the northwest corner needs to be sanded and repainted . <br /> 2. Clean-out needs to be set flush to the carpet at the northwest corner below the Johnson control box at EMD <br /> area 047 & Corridor 051 . <br /> 3 . Drywall around electrical outlet on the west wall to the left between EMD 047 & Door 050A, drywall needs <br /> to be sanded and repainted around the electrical outlet and then to the left and right of this area, drywall is <br /> irregular needs to be patched and repaired. Also the vinyl base in this area is scuffed. <br /> 4 . Drywall to the left of Door 050A needs to be sanded and repainted above the vinyl base approximately 18-24 <br /> inches and drywall above the door frame of 050A needs to be repainted, fingerprints on the paint. <br /> 5 . Drywall between Door 050A and 051 , approximately 6ft. to the left of Door 050A and about 6ft. off the floor, <br /> dent in the drywall. Also, on this wall between Door 050A and 051 in numerous area are scuff marks , dirt <br /> marks, etc. need to be sanded and cleaned. <br /> 6. Right and left sides of jambs of drywall between hollow metal jambs 051 needs to be sanded and repainted, <br /> drywall is very irregular. <br /> 7 . Bottom left of Door 051 on the east wall just above the vinyl base drywall is irregular in this area. <br /> 8 . To the right of Door 003B drywall needs to be sanded and repainted. That is also true of the left side above <br /> the vinyl base. <br /> 9 . Drywall to the right of hollow metal opening 052 - Men' s Vestibule drywall needs to be sanded and repainted <br /> approximately 8- 10 inches up the wall . <br /> 10. Ceramic tile floor and carpet needs to have transition strip installed. <br /> 11 . To the right of the drinking fountain area on the south end, drywall is irregular in this area needs to be sanded <br /> and repainted. <br /> 12. Top right comer at dropped header, drywall has crack in it, needs to be sanded, patched and repaired. <br /> 13. Ceramic tile where it abuts the drywall ceiling has no grout installed, void between the tile and the drywall, <br /> needs to be corrected and properly cut in. <br /> 14. Left edge of the drinking fountain area where the drywall abuts the ceramic tile, needs to be sanded and <br /> finished smooth and repainted . <br /> 15. Drywall between drinking fountain and opening to Women ' s Vestibule 057 at the center, irregularities in the <br /> drywall patched area still visible, needs to be sanded, patched and repaired. <br /> 16. Outside corner at the intersection of Corridor 046 and 051 , left or northeast corner of Vestibule 057 needs to <br /> be patched, sanded and repainted. <br /> 17 . Ceiling grid along the east wall to either side of the drinking fountain is not setting flush to the wall . Wall is <br /> not built straight and plumb, this is an issue and needs to be taken care of. <br /> 18. Paint finish in this area fingerprints, roller marks, etc. , visible, this needs to be corrected. <br /> General Notes: <br /> 1 . All closures need to be adjusted to meet the ADA 51b Closing Force. <br /> 2. All view light window wood frame holes for the fasteners need to be filled in. <br /> 3 . All silencers need to be installed in the hollow metal door frames. <br /> 4. All fire extinguisher cabinets need to be caulked where they abut the drywall. <br /> 5. All flush valves need to be checked to make sure there are batteries installed. Toilets not flushing. <br /> D O N A D I O <br /> & Associates, Architects, P.A . <br />