My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2009-192
CBCC
>
Official Documents
>
2000's
>
2009
>
2009-192
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2016 11:41:36 AM
Creation date
9/30/2015 11:37:50 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
07/14/2009
Control Number
2009-192
Agenda Item Number
8.I.
Entity Name
DeAngelis Diamond Construction
Subject
Contract IRC Parks Maintenance Complex
Area
5500 77th St.
Project Number
0701
Bid Number
2009043
Supplemental fields
SmeadsoftID
6815
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
478
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
equal, Style- cast satin finish aluminum, Font- Univers 67, Mount- Projected Spacer Mount- <br /> PSM. Note : The Sign Schedule on page 10440-5 has the Storage Bay and Maintenance <br /> Building labeled in reverse. A corrected page 10440-5 is herewith provided as revised 27 April <br /> 2009. <br /> Item #28 : Specifications Section 13122 : Article 2. 09 (C) Note : No metal or steel members on this project <br /> require spray on fire protection. <br /> Item #29 : Specifications Section 05030- Page 05030- 1 has been replaced with the (Revised 27 April <br /> 2009) sheet attached. <br /> Item #30 : Table of Contents : A revised page of the Table of Contents with Divisions 4 through 9 is <br /> attached to replace the original page issued. A revised page of the Table of Contents (Sections <br /> 16120 through 16965) is attached to replace the original page issued (Sections 16120 through <br /> 16511 ). <br /> Item #31 : Specification Section 07160-Underslab Vapor Retarder: Under Article 2 .01 , Manufacturer; An <br /> approved additional Manufacturer is "Viper" Products. Model VaporCheck II, 15-mil Under <br /> Slab Vapor Barrier, meeting ASTM E 1745 , Class-A, installed in strict compliance with <br /> manufacturer' s instructions. Representative is www.insulationsolutions .com. <br /> Item #32 : Location of Power Transformer: The serving electric utility has yet to establish a transformer <br /> location. Given there is an overhead line across the front of the building and it is to remain, an <br /> overhead transformer bank with a riser and service lateral to the meter socket would be the most <br /> economical choice for the office and maintenance buildings. This will be our recommendation <br /> to the Utility Company. Due to distance, and no need for three phase service, the storage bay <br /> building has it' s own service. The design assumes that a single phase padmounted transformer <br /> would be set 4 foot away from the existing meter socket location on the south wall of the <br /> building. Two (2) concrete filled, 6 inch diameter, steel protection posts with high visibility <br /> yellow vinyl covers will be required. The footprint of the contractor supplied transformer pad is <br /> 4 ' X 4 ' X 4 inches thick, reinforced with frbermesh. Alternatively, if the service-lateral would <br /> be less than 300 feet in length, an overhead transformer on a pole line would suffice. For <br /> bidding purposes utilize the transformer pad option. <br /> Item #33 : Specification for Fire Detection and Alarm System: Section 16965- See attached specification <br /> section that applies to this project. <br /> Item #34 : Generator Transfer Switch : The MTS is a manual Transfer Switch and shall be 2 Pole in lieu of <br /> the 3 Pole as shown on the plans Sheet E-6, Building Riser Diagram. A 60kw Generator Set <br /> shall be installed by the Contractor. <br /> Item #35: Electrical Conduit: Conduits approved for use on this project are specified in Notes 12, 13 , and <br /> 14 of Sheet E- 1 . MC Cable shall only be used in locations where it is readily replaceable. This <br /> condition shall exclude it' s use in the Administration Building, where the replacement of MC <br /> cable would disrupt operations and/or require restoration work. <br /> - 5 — <br /> F:IEngineeringl Capital Projectsl0701 IRCPARXS COMPLEXIAddendums1IRC Parks Maintenance Complex Addendum #1.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.