Laserfiche WebLink
W <br />4. Roadway/Off Site Drainage — All inverts; manhole top elevation; grate top <br />elevations. <br />5. Retention Ponds — Perimeter elevations, grade breaks, depths, and <br />,. calculate pond area at control elevation and grade breaks above water <br />surface. <br />6 Road:A:ay: <br />r a. Elevations of PVI at Profile Grade Line (PGL). <br />b. Edge of pavement elevations at curb inlets. <br />c. Survey Control: Install/re-establish new roadway alignment control <br />+. points (Survey Baseline or controlling line and all points as indicated on <br />the plans or control sheet) upon final roadway completion. Include all <br />intersections and side streets. Latitude, departure and elevations for all <br />+r control points. <br />d. Either if shown on plans or not: Any Public Land Corner or <br />Governmental Survey Control point(s) destroyed and/or disturbed <br />r6 during the scope of the project shall be properly re-established as per <br />standards as set forth within Florida Statutes, Administrative code and <br />Minimum Technical Standards for that type of survey. All said surveying <br />an mentioned above shall be performed under the direct supervision of a <br />registered Professional Surveyor and Mapper in the state of Florida and <br />certified accordingly. Said Governmental agency(s) shall be notified in <br />am writing of disturbance and re -establishments. <br />e. Stations and offsets, all structures. <br />1.3 AS-BUILTS <br />A. CONTRACTOR shall submit marked up Record Drawings to the OWNER. <br />ENGINEER will input As -Built information on Electronic Drawing files. <br />B. OWNER shall deliver to CONTRACTOR seven (7) sets of As-Builts plotted <br />from electronic files with the marked up Record Drawings. <br />~ C. CONTRACTOR's surveyor shall review, sign and seal As-Builts or Record <br />drawing(s). Said drawing(s) shall clearly state, type of survey, positional <br />tolerances, adhere and be certified to by a registered Professional <br />Surveyor and Mapper in the state of Florida, any standards set forth by <br />Florida Statutes, Administrative code and Minimum Technical Standards <br />„„ for As-Built/Record surveys CONTRACTOR shall return marked up <br />Record Drawings and six (6) sets of signed and sealed As-Builts to <br />OWNER. <br />W 01720-2 01720 Record Documents <br />F:1Engineering\Capital Projects19611-CR 512 Widening19611 CR 512 PHASE MContract Documents10001-01720 - Record <br />Documents.doc <br />7 <br />1W <br />