Laserfiche WebLink
1 . 2 SOME PERMITS TO BE OBTAINED BY THE CONTRACTOR <br /> A. The OWNER has obtained certain permits for this project and they are listed in <br /> paragraph SC-6 . 08 of the Supplementary Conditions . Per paragraph SC . <br /> 6 . 08 . 13 of the Supplementary Conditions , the CONTRACTOR shall apply for, <br /> obtain , and pay for all other required permits and licenses . This may include <br /> but not be limited to : <br /> 1 . Long -term or short-term dewatering permit as required by the St. Johns <br /> River Water Management District (SJRWMD) . Contact SJRWMD at <br /> (321 ) 9844940 to determine which permit is required and the associated <br /> statutory requirements ; and <br /> 2 . The State of Florida Generic Permit for Stormwater Discharge From <br /> Large and Small Construction Activities . Contact the Florida <br /> Department of Environmental Protection ( FDEP ) at (866) 336-6312 <br /> (toll free) or (850) 245-7522 or <br /> www , dep , state . fl . us/water/stormwater/ npdes/ <br /> 3 . Florida Department of Environmental Protection <br /> ( FDEP ) " Notice of Intent to Use Generic Permit for Stormwater <br /> Discharge From Construction Activities That Disturb one or More <br /> Acres of Land and Contributes stormwater discharges to surface <br /> waters of the State or into a municipal separate storm sewer system <br /> ( MS4) permit application form . Contact FDEP at (407) 894-7555 or <br /> (850 ) 921 -9904 ; and <br /> 4 . U . S . Environmental Protection Agency ( EPA) Notice of Intent ( NOI ) <br /> for Storm Water Discharges Associated With Construction Activity <br /> Under a NPDES General Permit . " <br /> B . Provide copies of all permits to the OWNER and ENGINEER and comply with <br /> all conditions contained in all permits at no extra cost to the OWNER . If there is <br /> a conflict between any permit requirement and these Specifications , the more <br /> stringent specification or requirement shall govern . <br /> 1 . 3 GENERAL <br /> A . Do not begin any other construction work until the pollution control and <br /> treatment system has been constructed in accordance with approved plans and <br /> approved for use by the OWNER and applicable permitting authorities . <br /> B . From time to time , the OWNER or ENGINEER will inspect the pollution control <br /> and treatment system and may take effluent samples for analysis by a testing <br /> laboratory selected and paid for by the OWNER . If at any time , the OWNER or <br /> ENGINEER determines that the pollution control and treatment system is not in <br /> compliance with the approved system , the OWNER or ENGINEER will shut the <br /> portion of the project down that is not in compliance , and it shall remain shut= <br /> down until the pollution control and treatment system is properly constructed or <br /> repaired , and complies with the approved pollution control and treatment <br /> 01025-5 Technical Specifications <br /> FAEngineering\Capital Projects\0217-Powerline Road\Bid Documents\Technical Specifications .doc <br />