2008-276 B
CBCC
>
Official Documents
>
2000's
>
2008
>
2008-276 B
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/11/2016 10:20:30 AM
Creation date
10/1/2015 12:34:00 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
09/09/2008
Control Number
2008-276B
Agenda Item Number
8.DD.
Entity Name
Interstate Engineering Corp.
Subject
South RO Water Treatment Plant Improvements Supplementary Conditions
Area
South County RO Water Treatment Plant
Project Number
UCP2859
Bid Number
2008027
Supplemental fields
SmeadsoftID
7556
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
b . Supplier <br /> C . Manufacturer <br /> 5 . Identification of the product, with the section number, page and paragraph(s). <br /> 6 . Field dimensions, clearly identified as such. <br /> 7 . Relation to adjacent or critical features of the work or materials . <br /> 8 . Applicable standards , such as ASTM or Federal Standards numbers . <br /> 9 . Identification of deviations from Contract Documents . <br /> 10 . Identification of revisions on resubmittals . <br /> IL A blank space suitably sized for Contractor and Engineer stamps . <br /> 12 . Contractor ' s stamp or review and approval , initialed or signed , certifyirâ–ºg to review <br /> of initialed or signed, certifying to review of submittal , verification of products, field <br /> measurements and field construction criteria, and coordination of the information <br /> within the submittal with requirements of the work and of Contract Documents . <br /> 13 . Where calculations are required to be submitted by the Contractor, the <br /> calculations shall have been checked by a qualified individual other than the <br /> preparer. The submitted calculations shall clearly show the names of the preparer <br /> and of the checker. <br /> 1 .05 REVIEW OF SHOP DRAWINGS , PRODUCT DATA, WORKING DRAWINGS AND <br /> SAMPLES <br /> A. The review of shop drawings, data and samples will be for general conformance with the <br /> design concept and Contract Documents. They shall not be construed : <br /> 1 , as permitting any departure from the Contract requirements; <br /> 2 , as relieving the Contractor of responsibility for any errors, including details, <br /> dimensions, and materials; <br /> 3 , as approving departures from details furnished by the Engineer, except as <br /> otherwise provided herein. <br /> B . The Contractor remains responsible for details and accuracy, for coordinating the work <br /> with all other associated work and trades, for selecting fabrication processes, for <br /> techniques of assembly, and for performing work in a safe manner. <br /> C. If the shop drawings, data or samples as submitted describe variations and show a <br /> departure from the Contract requirements which Engineer finds to be in the interest of the <br /> Owner and to be so minor as not to involve a change in Contract Price or Contract Time, <br /> the Engineer may return the reviewed drawings without noting an exception. <br /> D . When reviewed by the Engineer each of the Shop Drawings will be identified as having <br /> received such review being so stamped and dated. Shop Drawings stamped <br /> "REVIEWED, COMMENTS AS NOTED" OR "REJECTED, REVISE AND <br /> RESUBMIT" and with required corrections shown will be returned to the Contractor for <br /> correction and resubmittal. <br /> E. Resubmittals will be handled in the same manner as first submittals. On resubmittals the <br /> Contractor shall identify all revisions made to the submittals, either in writing on the letter 4 <br /> of transmittal or on the shop drawings by use of revision triangles or othersimilar <br /> methods . The resubmittal shall clearly respond to each comment made by the Engineer on <br /> the previous submission. Additionally, the Contractor shall direct specific attention to any <br /> 044572017 <br /> 01340-4 <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.