Laserfiche WebLink
b. Supplier <br />C. Manufacturer <br />5. Identification of the product, with the section number, page and paragraph(s). <br />6. Field dimensions, clearly identified as such. <br />7. Relation to adjacent or critical features of the work or materials. <br />8. Applicable standards, such as ASTM or Federal Standards numbers. <br />9. Identification of deviations from Contract Documents. <br />10. Identification of revisions on resubmittals. <br />IL A blank space suitably sized for Contractor and Engineer stamps. <br />12. Contractor's stamp or review and approval, initialed or signed, certifyirâ–ºg to review <br />of initialed or signed, certifying to review of submittal, verification of products, field <br />measurements and field construction criteria, and coordination of the information <br />within the submittal with requirements of the work and of Contract Documents. <br />13. Where calculations are required to be submitted by the Contractor, the <br />calculations shall have been checked by a qualified individual other than the <br />preparer. The submitted calculations shall clearly show the names of the preparer <br />and of the checker. <br />1.05 REVIEW OF SHOP DRAWINGS, PRODUCT DATA, WORKING DRAWINGS AND <br />SAMPLES <br />A. The review of shop drawings, data and samples will be for general conformance with the <br />design concept and Contract Documents. They shall not be construed: <br />1, as permitting any departure from the Contract requirements; <br />2, as relieving the Contractor of responsibility for any errors, including details, <br />dimensions, and materials; <br />3, as approving departures from details furnished by the Engineer, except as <br />otherwise provided herein. <br />B. The Contractor remains responsible for details and accuracy, for coordinating the work <br />with all other associated work and trades, for selecting fabrication processes, for <br />techniques of assembly, and for performing work in a safe manner. <br />C. If the shop drawings, data or samples as submitted describe variations and show a <br />departure from the Contract requirements which Engineer finds to be in the interest of the <br />Owner and to be so minor as not to involve a change in Contract Price or Contract Time, <br />the Engineer may return the reviewed drawings without noting an exception. <br />D. When reviewed by the Engineer each of the Shop Drawings will be identified as having <br />received such review being so stamped and dated. Shop Drawings stamped <br />"REVIEWED, COMMENTS AS NOTED" OR "REJECTED, REVISE AND <br />RESUBMIT" and with required corrections shown will be returned to the Contractor for <br />correction and resubmittal. <br />E. Resubmittals will be handled in the same manner as first submittals. On resubmittals the <br />Contractor shall identify all revisions made to the submittals, either in writing on the letter <br />of transmittal or on the shop drawings by use of revision triangles or other similar <br />methods. The resubmittal shall clearly respond to each comment made by the Engineer on <br />the previous submission. Additionally, the Contractor shall direct specific attention to any <br />044572017 <br />01340-4 <br />