Laserfiche WebLink
3 .04 SHOP PAINTING <br /> A. Before exposure to weather and prior to shop painting, all surfaces shall be thoroughly <br /> cleaned, dry and free from all mill -scale, rust, grease, dirt and other foreign matter. <br /> B . All pumps and motors shall be shop primed with primer compatible with field painting as <br /> specified in Division 9 . <br /> C . All nameplates shall be properly protected during painting. <br /> D . Gears , bearing surfaces , and other similar surfaces obviously not to be painted shall be given <br /> a heavy shop coat of grease or other suitable rust resistant coating. This coating shall be <br /> maintained as necessary to prevent corrosion during periods of storage and erection and shall <br /> be satisfactory to the Engineer up to the time of the final acceptance test <br /> 3 .05 INSTALLATION <br /> A. Install all equipment in strict conformance with the manufacturer ' s specifications and <br /> industry standards . Perform all work in a workmanlike manner. <br /> B . Manufacturer ' s representative for pumps shall inspect installation for correctness and <br /> compliance with manufacturer' s specifications and submit written certification that <br /> equipment is ready to be placed in service. <br /> C . No piping connecting any of the equipment shall be jacked, pried or forced in to position in <br /> any way. All piping must mate perfectly with the equipment it is attaching prior to <br /> installation of flange bolts or other connecting devices. <br /> D . Prepare existing concrete pedestal as needed for installation of proposed pumping units. <br /> E . No more than one high service pump can be out of service at any time . No high service <br /> pump can be out of service for any longer than 10 days during the replacement/start-up <br /> process. <br /> F . The contractor shall coordinate with Hudson Pump so that the pump rehabilitation of the <br /> shelf spare can be performed onsite once one of the existing high service pumps has been <br /> removed from service . Contact Jim Walton with Hudson Pump at 863 -66547867 to <br /> coordinate costs and scheduling of work. Rehabilitation of the one ( 1 ) high service pump <br /> must be coordinated with the Owner as to not interrupt water plant operations. The contractor <br /> shall be responsible to store the shelf spare pump as directed by the Owner. <br /> G. Each high service pump must be installed, tested, disinfected, and fully operational before <br /> removing the next high service pump. <br /> 3 .06 START-UP <br /> A. The pump manufacturer shall have a qualified representative mate the pump to the motor. <br /> Manufacturer must provide a qualified representative on-site for a minimum of one day to <br /> certify the pump installation and confirm pump performance. <br /> 044572017 <br /> 11934-9 <br />