My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2008-276 D
CBCC
>
Official Documents
>
2000's
>
2008
>
2008-276 D
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/11/2016 10:29:43 AM
Creation date
10/1/2015 12:34:52 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
09/09/2008
Control Number
2008-276 D
Agenda Item Number
8.DD.
Entity Name
Interstate Engineering Corp.
Subject
South RO Water Treatment Plant Improvements Material and Equipment
Area
South RO Water Treatment Plant
Project Number
UCP 2859
Bid Number
2008027
Supplemental fields
SmeadsoftID
7558
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
B . Fittings used with flexible conduit shall be of the screw-in type as manufactured by the Thomas <br /> and Betts Company, Crouse-Hinds Company, or approved equal . <br /> 2 .03 FLEXIBLE COUPLINGS <br /> A . Flexible couplings shall be as manufactured by the Crouse-Hinds Company , Appleton Electric <br /> Company , or approved equal . <br /> 2 .04 BOXES AND FITTINGS <br /> A _ Combination expansion-deflection fittings shall be Type XD as manufactured by the Crouse- <br /> Hinds Company or approved equal . <br /> B . Terminal boxes, junction boxes , pull boxes , etc . , shall be of the same material as the raceway <br /> unless otherwise shown on the Drawings . Covers shall be gasketed and fastened with stainless <br /> steel screws . Boxes shall be as manufactured by Hoffman Engineering Company or approved <br /> equal . <br /> C . Conduit hubs shall be as manufactured by Meyers Electric Products, Inc . , Raco Division, <br /> Appleton Electric Company, or approved equal . <br /> PART 3 - EXECUTION <br /> 3 .01 INSTALLATION <br /> A. No conduit smaller than %2 inch electrical trade size shall be used, nor shall any have more than <br /> four (4) 90 degree bends in any one run. Pull boxes shall be provided as required or directed. <br /> Minimum size in floor slabs shall be % inch. <br /> B . An equipment grounding conductor sized per article 250-95 of the N.E .C . shall be installed in <br /> every raceway whether or not shown on the Drawings . <br /> B . All underground conduit shall be buried at least 24 inches below grade. <br /> D. A three (3) inch wide warning tape, red with black stenciled letters " CAUTION - CAUTION - <br /> CAUTION ELECTRICAL LINE BURIED BELOW " shall be installed at least 12 inches <br /> above, and along the entire length of all underground conduit. <br /> E. No wire shall be pulled until the conduit system is complete in all details, or in the case of <br /> concealed work, until all rough plastering or masonry has been completed. <br /> F. The ends of all conduits shall be tightly plugged to exclude dust and moisture while under <br /> construction. <br /> G. Conduit supports shall be spaced at intervals of eight (8) feet or less, as required to obtain rigid <br /> construction. <br /> H. Single conduits shall be supported by means of one-hole pipe clamps in combination with one- i <br /> screw back plates, to raise conduits from the surface. <br /> 044572017 <br /> 16110 - 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.